SolutionMall
Partner CRM
  • English
  • 中文
  • Français
  • Español
  • Português
  • Русский
Browse Products
🔥Solution 03 · Petrochemical

Petrochemical Explosion-Proof Engineering Solution

Complete ATEX/IECEx certified intrinsically safe instruments and explosion-proof tools for refineries, chemical plants, LNG terminals and offshore platforms — covering Zone 0/1/2 hazardous area operations.

Zone 0/1/2
Hazardous Area
ATEX/IECEx
Certification
Ex ia/ib/d
Protection Type
Petrochemical Plant
🎯

Core Value & Target Users

Refineries, chemical plants, LNG terminals, offshore platforms and gas processing facilities

🔍
Risk Control
ATEX/IECEx certified instruments prevent ignition in Zone 0/1/2 areas, eliminating the risk of electrical sparks triggering explosions in flammable gas environments.
🛡️
Regulatory Compliance
ATEX and IECEx certified equipment ensures full compliance with international explosion-proof standards, avoiding costly shutdowns and regulatory penalties.
💼
Operational Efficiency
Rugged instruments withstand harsh chemical environments, reducing equipment replacement frequency and lowering total cost of ownership.
🗺️

Explosion-Proof System Topology

Three zones: Hazardous Area (Zone 0/1) → Interface (Zone 2) → Safe Area

PETROCHEMICAL EXPLOSION-PROOF SYSTEM TOPOLOGY ZONE 0 / ZONE 1 — HAZARDOUS AREA Ex ia Multimeter ATEX Zone 0 | 1000V Ex Gas Detector LEL/O2/CO/H2S Ex Thermal Imager Zone 1 Rated | ±2°C Ex Clamp Meter AC/DC 1000A Ex Insulation Tester IECEx | 5kV Ex Pressure Gauge 0–600 bar | SS316 Ex Portable Tools (Zone 1) Non-sparking wrench, Ex flashlight, Ex radio ZONE 2 / SAFE AREA INTERFACE Zener Barrier / Galvanic Isolator IEC 60079-11 | Entity concept Ex Junction Box IP66 | ATEX II 2G | Cable glands Ex Control Panel Zone 2 rated | Stainless steel Gas Detection Controller Multi-channel | Alarm relay output SAFE AREA — CONTROL & MANAGEMENT DCS / SCADA System IEC 61511 | Functional safety | SIL rated Gas Detection Alarm Panel Audible/visual alarm | Emergency shutdown Calibration Laboratory ISO 17025 | Traceable calibration SolutionMall Platform Ex-certified tools & instruments supply Zone 0/1 Hazardous Zone 2 Interface Safe Area SolutionMall – Tools & Instruments Division

Fig. 1: Petrochemical Explosion-Proof System Topology

📦

Key Products in This Solution

All products ATEX/IECEx certified for hazardous area use

⚡
Ex ia Intrinsically Safe Multimeter
ATEX Zone 0 | 1000V CAT III | IEC 60079-11
🔬
Portable Gas Detector (Ex)
LEL/O2/CO/H2S | ATEX II 1G | Audible/visual alarm
🌡️
Ex Thermal Imaging Camera
Zone 1 rated | 160×120px | ±2°C | IECEx certified
📐
Ex Clamp Meter
ATEX Zone 1 | AC/DC 1000A | True RMS
🔧
Non-Sparking Tool Set
Beryllium copper / Aluminum bronze | ATEX compliant
🔩
Ex Insulation Resistance Tester
IECEx | 5kV | Auto-discharge | Polarization index
💡
Ex LED Flashlight
ATEX Zone 1 | IP68 | 500 lm | Rechargeable
📡
Fixed Gas Detection System
Multi-point | 4-20mA output | IEC 61511
🔌
Ex Pressure Gauge
0–600 bar | SS316L | ATEX II 1G | Glycerine filled
⚙️
Ex Zener Safety Barrier
IEC 60079-11 | Entity concept | DIN rail mount
🔄

Standard Operating Workflow

8-step process from hazard assessment to safe operations

1
Hazardous Area Classification (ATEX/IECEx)
2
Equipment Selection by Zone & Gas Group
3
Certificate Verification & Documentation
4
Installation by Certified Personnel
5
Gas Detection System Commissioning
6
Instrument Calibration & Bump Test
7
Periodic Inspection & Maintenance
8
Annual ATEX Audit & Recertification
📋

Applicable Standards & Certifications

CategoryStandardScopeMandatory
Ex Equipment ClassificationIEC 60079-0General requirements for explosive atmospheresYes
Intrinsic SafetyIEC 60079-11Ex ia/ib protection concept, entity parametersYes
Flameproof EnclosureIEC 60079-1Ex d protection, enclosure design and testingYes
Functional SafetyIEC 61511Safety instrumented systems for process industryYes
Gas DetectionIEC 60079-29Performance requirements for gas detectorsYes
Area ClassificationIEC 60079-10Hazardous area classification methodologyRecommended
💡

Selection Recommendations & Deployment Notes

🔥
Zone Determines Equipment
Zone 0 requires Ex ia (intrinsically safe Category 1). Zone 1 allows Ex ia, Ex ib, Ex d. Zone 2 allows Ex n (non-sparking). Never use lower-rated equipment in higher-risk zones.
📄
Verify Certificates Before Use
Always verify ATEX/IECEx certificate numbers on the IECEx website before use. Counterfeit Ex equipment is a serious safety risk and regulatory violation.
⚙️
Calibrate Gas Detectors Regularly
Portable gas detectors must be bump-tested before each use and fully calibrated at least every 6 months. Sensor drift is the leading cause of false negatives.
🔍
Non-Sparking Tools are Mandatory
Standard steel tools can generate sparks when struck. In Zone 1/2 areas, use beryllium copper or aluminum bronze non-sparking tools for all mechanical work.
🏭 Oil Refineries
⚗️ Chemical Plants
🚢 LNG Terminals
🌊 Offshore Platforms
🔥 Gas Processing Facilities
⛽ Fuel Storage Terminals
🏗️ Petrochemical Construction
🔬 Pharmaceutical Manufacturing

Ready to Deploy This Solution?

Our engineering team provides ATEX/IECEx compliance consulting, product selection, and project support for hazardous area operations worldwide.

← PREVIOUS SOLUTION Renewable Energy Station Construction NEXT SOLUTION → Building Construction High-Altitude Work →